PASS GUARANTEED FIRST-GRADE FORTINET NSE7_LED-7.0 - FORTINET NSE 7 - LAN EDGE 7.0 DUMPS

Pass Guaranteed First-grade Fortinet NSE7_LED-7.0 - Fortinet NSE 7 - LAN Edge 7.0 Dumps

Pass Guaranteed First-grade Fortinet NSE7_LED-7.0 - Fortinet NSE 7 - LAN Edge 7.0 Dumps

Blog Article

Tags: NSE7_LED-7.0 Dumps, Actual NSE7_LED-7.0 Test, Hot NSE7_LED-7.0 Questions, PDF NSE7_LED-7.0 Cram Exam, NSE7_LED-7.0 Interactive Course

BTW, DOWNLOAD part of Fast2test NSE7_LED-7.0 dumps from Cloud Storage: https://drive.google.com/open?id=1YpaKIxC5lVbozJf9bRajHbAP9aBOCXba

Our website gives detailed guidance to our customers for preparation of NSE7_LED-7.0 actual test and take them towards the direction of achievement. Each of our Fortinet exam preparation materials is designed by IT professionals in order to improve your particular skills. Our NSE7_LED-7.0 Practice Questions will boost the confidence of candidates for appearing in the real exam.

The Fortinet NSE 7 - LAN Edge 7.0 certification exam covers a wide range of topics, including network design, routing, switching, wireless LANs, virtual private networks (VPNs), and network security. Candidates will be tested on their ability to plan, configure, and troubleshoot LAN Edge solutions using Fortinet products such as FortiGate, FortiSwitch, and FortiAP.

Passing the NSE7_LED-7.0 Exam requires a deep understanding of Fortinet solutions and network security concepts. Candidates must be able to analyze network traffic and identify security threats, as well as configure and manage Fortinet solutions to mitigate these threats. Successful candidates will have the skills and knowledge to design and implement LAN edge security solutions that meet the requirements of modern businesses.

>> NSE7_LED-7.0 Dumps <<

Fortinet NSE7_LED-7.0 Questions - Pass Exam and Get Career Benefits

Many candidates compliment that Fortinet NSE7_LED-7.0 study guide materials are best assistant and useful for qualification exams, they have no need to purchase other training courses or books to study, and only by practicing our Fortinet NSE7_LED-7.0 Exam Braindumps several times before exam, they can pass exam in short time easily.

Fortinet NSE7_LED-7.0 Exam is a comprehensive assessment that tests an individual's knowledge and proficiency in Fortinet's network security solutions. NSE7_LED-7.0 exam covers a wide range of topics related to LAN Edge 7.0, and passing the exam can lead to the highly sought-after Fortinet NSE 7 - LAN Edge 7.0 certification. Fortinet NSE 7 - LAN Edge 7.0 certification is a great way for IT professionals to enhance their career prospects in the network security field and demonstrate their commitment to their profession.

Fortinet NSE 7 - LAN Edge 7.0 Sample Questions (Q32-Q37):

NEW QUESTION # 32
Refer to the exhibit.

Examine the FortiManager configuration and FortiGate CLI output shown in the exhibit An administrator is testing the NAC feature The test device is connected to a managed FortiSwitch device
{S224EPTF19"53€7)onport2
After applying the NAC policy on port2 and generating traffic on the test device the test device is not matching the NAC policy therefore the test device remains m the onboarding VLAN Based on the information shown in the exhibit which two scenarios are likely to cause this issue? (Choose two.)

  • A. The MAC address configured on the NAC policy is incorrect
  • B. The device operating system detected by FortiGate is not Linux
  • C. Management communication between FortiGate and FortiSwitch is down
  • D. Device detection is not enabled on VLAN 4089

Answer: B,D

Explanation:
According to the FortiManager configuration, the NAC policy is set to match devices with the MAC address of 00:0c:29:6a:2b:3c and the operating system of Linux. However, according to the FortiGate CLI output, the test device has a different MAC address of 00:0c:29:6a:2b:3d. Therefore, option B is true. Option A is also true because the FortiSwitch device status is shown as down, which means that the management communication betweenFortiGate and FortiSwitch is not working properly. This could prevent the NAC policy from being applied correctly. Option C is false because the device operating system detected by FortiGate is Linux, which matches the NAC policy. Option D is false because device detection is enabled on VLAN 4089, as shown by the command "config switch-controller vlan".


NEW QUESTION # 33
Which EAP method requires the use of a digital certificate on both the server end and the client end?

  • A. PEAP
  • B. EAP-GTC
  • C. EAP-TTLS
  • D. EAP-TLS

Answer: D

Explanation:
Explanation
According to the FortiGate Administration Guide, "EAP-TLS is the most secure EAP method. It requires a digital certificate on both the server end and the client end. The server and client authenticate each other using their certificates." Therefore, option D is true because it describes the EAP method that requires the use of a digital certificate on both the server end and the client end. Option A is false because EAP-TTLS only requires a digital certificate on the server end, not the client end. Option B is false because PEAP also only requires a digital certificate on the server end, not the client end. Option C is false because EAP-GTC does not require a digital certificate on either the server end or the client end.


NEW QUESTION # 34
A wireless network in a school provides guest access using a captive portal to allow unregistered users to self-register and access the network. The administrator is requested to update the existing configuration to provide captive portal authentication through a secure connection (HTTPS).
Which two changes must the administrator make to enforce HTTPS authentication? (Choose two)

  • A. Disable HTTP administrative access on the guest SSID to enforce HTTPS connection
  • B. Enable HTTP redirect in the user authentication settings
  • C. Update the captive portal URL to use HTTPS on FortiGate and FortiAuthenticator
  • D. Create a new SSID with the HTTPS captive portal URL

Answer: B,C

Explanation:
To enable HTTPS authentication, you must enable HTTP redirect in the user authentication settings. This redirects HTTP requests to HTTPS. You must also update the captive portal URL to use HTTPS on both FortiGate and FortiAuthenticator.


NEW QUESTION # 35
Refer to the exhibit.

Examine the FortiSwitch security policy shown in the exhibit
If the security profile shown in the exhibit is assigned to all ports on a FortiSwitch device for 802 1X authentication which statement about the switch is correct?

  • A. FortiSwitch will assign non-802 1X devices to the onboarding VLAN
  • B. All EAP messages will be terminated on FortiSwitch
  • C. FortiSwitch cannot authenticate multiple devices connected to the same port
  • D. FortiSwitch will try to authenticate non-802 1X devices using the device MAC address as the username and password

Answer: A

Explanation:
According to the FortiSwitch Administration Guide, "If a device does not support 802.1X authentication, you can configure the switch to assign the device to an onboarding VLAN. The onboarding VLAN is a separate VLAN that you can use to provide limited network access to non-802.1X devices." Therefore, option C is true because it describes the behavior of FortiSwitch when the security profile shown in the exhibit is assigned to all ports. Option A is false because FortiSwitch can authenticate multiple devices connected to the same port using MAC-based or MAB-EAP modes. Option B is false because FortiSwitch will not try to authenticate non-802.1X devices using the device MAC address as the username and password, but rather use MAC authentication bypass (MAB) or EAP pass-through modes. Option D is false because all EAP messages will be terminated on FortiGate, not FortiSwitch, when using 802.1X authentication.


NEW QUESTION # 36
Refer to the exhibit. In the wireless configuration shown in the exhibits, an AP is deployed in a remote site and has a wireless network (VAP) called Corporate deployed to it. The network is a tunneled network however clients connecting to a wireless network require access to a local printer. Clients are trying to print to a printer on the remote site but are unable to do so.
Which configuration change is required to allow clients connected to the Corporate SSID to print locally?

  • A. Configure split-tunneling in the vap configuration
  • B. Disable the Block Intra-SSID Traffic (intra-vap-privacy) setting on the SSID (VAP) profile
  • C. Configure the printer as a wireless client on the Corporate wireless network
  • D. Configure split-tunneling in the wtp-profile configuration

Answer: A

Explanation:
Split tunneling allows you to specify which traffic is tunneled to the FortiGate and which traffic is sent directly to the Internet. This can improve performance and reduce bandwidth usage.
Therefore, by configuring split-tunneling in the vap configuration, you can allow the clients connected to the Corporate SSID to access both the corporate network and the local printer.


NEW QUESTION # 37
......

Actual NSE7_LED-7.0 Test: https://www.fast2test.com/NSE7_LED-7.0-premium-file.html

BTW, DOWNLOAD part of Fast2test NSE7_LED-7.0 dumps from Cloud Storage: https://drive.google.com/open?id=1YpaKIxC5lVbozJf9bRajHbAP9aBOCXba

Report this page